Cooper&Hunter NORDIC EVO CH-S18FTXN-E2wf
Elegant LED display, hidden when the unit is off,
Controlled by step-less regulation technology, the fan speed be adjust 1% to 100% between the highest and lowest speed,
Operating temperature range: cooling from +18°С to +48°C, heating from -23°С to +24°C
Model |
CH-S18FTXN-E2wf |
||
Capacity |
cold/warm |
kW |
5.13 (1.00-6.70)/5.27 (1.10-6.80) |
Electric power supply |
~ 220-240V/50Hz/1Ph |
||
Rated input |
cold/warm |
kW |
1.19 (0.32-2.56)/1.138 (0.35-2.30) |
Energy performance |
EER (Cold)/C.O.P. (Warm) |
kW/kW |
4.32/4.63 |
SEER*/SCOP** |
6.3 (A ++)/4.8 (A++) |
||
Air productive capacity |
m3/h |
850/720/610/520 |
|
Sound-pressure level |
indoor unit/(max-min) outdoor unit |
dB(A) |
46/42/39/28 56 |
Type of refrigerant coolant |
R410A |
||
Dimensions (width/height/depth) |
indoor unit/outdoor unit |
mm |
972x302x224/960x700x396 |
Weight |
indoor unit/outdoor unit |
kg |
14/43 |
Compressor type |
rotor |
||
Drainage |
l/h |
1.8 |
|
Operational temperature range cooling |
°C |
+18/+48 |
|
Operational temperature range heating |
°C |
-23/+24 |
|
Gas charge volume |
kg |
1.25 |
|
Liquid pipeline diameter |
mm/inch |
6.35/1/4’’ |
|
Gas pipeline diameter |
mm/inch |
9.53/3/8’’ |
|
Maximum pipeline level difference |
m |
10 |
|
Pipeline maximum length |
m |
25 |
|
* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.